The X-Point Inspection™: all 233 checks

Most inspectors will not show you their checklist. Ours is right here: 233 checks across 15 areas, 35 specific to Manitoba and 26 measured with instruments.

Get an instant price

Some checks depend on the home: a condo has no roof for you to inspect, a city home has no well. Add-on items are marked in the list. Every inspection follows the Standards of Practice we commit to, and we note anything we could not inspect and why.

Grounds and drainage16

  1. Lot grading slopes away from the foundation
  2. Grade height against siding and window wells
  3. Downspout discharge distance and extensions
  4. Window well depth, drainage and covers
  5. Driveway and walkway cracking, heaving or settlement
  6. Patio and slab slope toward or away from the house
  7. Retaining walls: leaning, cracking, drainage
  8. Vegetation and trees close to the foundationManitoba
  9. Exterior stairs: rise, run and handrails
  10. Guards and railings on decks and landings
  11. Fences and gates attached to the house
  12. Swale and side-yard drainage pathsManitoba
  13. Sump discharge location and freeze riskManitoba
  14. Visible signs of past water pooling
  15. Exterior hose bibs and frost-free valvesManitoba
  16. Detached garage or shed: general condition

Roof and chimney18

  1. Roof covering type and estimated remaining life
  2. Missing, lifted, cupped or brittle shingles
  3. Granule loss and exposed matting
  4. Flashing at walls, chimneys and skylights
  5. Valley flashing and valley wear
  6. Drip edge and eave protection
  7. Ice dam evidence along eavesManitoba
  8. Plumbing vent stacks and boots
  9. Roof vents: type, number and condition
  10. Skylights: seals and staining
  11. Gutters: slope, debris, joints and fastening
  12. Soffit and fascia: damage or rot
  13. Chimney crown and cap
  14. Chimney masonry: spalling and mortar jointsManitoba
  15. Chimney height and clearances
  16. Roof structure sag visible from outside
  17. Drone or pole-camera views where walking is unsafeMeasured
  18. Number of layers where visible

Exterior walls, doors and windows18

  1. Siding type, gaps, cracks and loose sections
  2. Stucco cracking and moisture staining
  3. Brick or stone veneer: cracks, weep holes
  4. Caulking at penetrations and trim
  5. Exterior trim rot or damage
  6. Wall penetrations sealed (vents, cables, pipes)
  7. Exterior doors: weatherstripping and operation
  8. Door thresholds and sill flashing
  9. Window frames, sills and glazing seals
  10. Failed sealed units (fogging) where visible
  11. Window operation and locks (sample)
  12. Egress windows in bedrooms, including basementManitoba
  13. Exterior light fixtures and receptacles
  14. Gas meter clearance and protection
  15. Electrical service mast and drip loop
  16. Dryer and bath fan terminations
  17. Wall moisture readings at stained areasMeasured
  18. Thermal scan of exterior envelope (add-on)Measured

Decks, porches and garage14

  1. Deck ledger attachment and flashing
  2. Joist hangers and fasteners
  3. Posts, footings and frost heave signsManitoba
  4. Decking boards: rot, splits, fasteners
  5. Guard height and baluster spacing
  6. Stair stringers and landings
  7. Porch and covered-entry structure
  8. Garage slab cracking and heavingManitoba
  9. Garage door operation and auto-reverse test
  10. Garage door sensors and opener
  11. Fire separation between garage and house
  12. Self-closing door from garage to house
  13. Garage roof and wall structure
  14. Garage electrical receptacles (GFCI where required)

Foundation and structure20

  1. Foundation type and material
  2. Foundation cracks: width, pattern and directionMeasured
  3. Horizontal or stair-step cracking
  4. Differential settlement and heave signsManitoba
  5. Clay-soil movement indicators: sticking doors, drywall cracksManitoba
  6. Floor levelness surveyMeasured
  7. Wall plumb at key pointsMeasured
  8. Basement wall bowing or bulging
  9. Efflorescence and water staining
  10. Moisture readings at foundation wallsMeasured
  11. Beam and post condition and bearing
  12. Teleposts and adjustment historyManitoba
  13. Floor joists: notching, cutting, sag
  14. Sill plate and rim joist condition
  15. Rim joist insulation and air sealingManitoba
  16. Crawlspace access, vapour barrier, ventilation
  17. Wood-destroying insect and rot evidence
  18. Previous repairs: piers, braces, epoxy injections
  19. Basement slab cracking and heavingManitoba
  20. Underpinning or lowered basement signs

Basement water defence11

  1. Sump pit presence, lid and conditionManitoba
  2. Sump pump test run where safe
  3. Sump pump discharge and check valve
  4. Backup power or alarm for sumpManitoba
  5. Backwater valve presence and accessManitoba
  6. Floor drain condition and trap
  7. Weeping tile connection signsManitoba
  8. Signs of past basement flooding
  9. Musty odour and humidity readingMeasured
  10. Thermal scan for hidden moisture (add-on)Measured
  11. Sewer line scope recommendation for older homesManitoba

Heating20

  1. Heating system type and fuel
  2. Furnace age from data plate
  3. Burner flame and operation using normal controls
  4. Heat exchanger visible areas
  5. Venting: material, slope, joints and termination
  6. High-efficiency condensate drain
  7. Combustion air supply
  8. Filter type and condition
  9. Supply and return air temperature splitMeasured
  10. Heat delivered to each room (sample)Measured
  11. Ductwork: disconnected or damaged runs
  12. Humidifier condition and drain
  13. Heat recovery ventilator (HRV) presence and operationManitoba
  14. HRV filters and core
  15. Boiler, pumps and expansion tank (if present)
  16. Radiators and baseboards: leaks and valves
  17. Gas line, shutoff and bonding at appliance
  18. Carbon monoxide alarm near sleeping areas
  19. Electric baseboard heaters: clearances
  20. Fuel oil tank presence or removal evidenceManitoba

Cooling and ventilation10

  1. Air conditioner type and age
  2. Condenser level, clearances and fins
  3. Refrigerant line insulation
  4. Cooling temperature split (season permitting)Measured
  5. Condensate line and pump
  6. Heat pump operation (season permitting)
  7. Kitchen exhaust to exterior
  8. Bathroom fans: operation and termination
  9. Dryer vent material and length
  10. Whole-house moisture balance indicatorsManitoba

Plumbing22

  1. Water supply source and main shutoff
  2. Supply piping material (copper, PEX, galvanized, poly-B)
  3. Water pressure at fixturesMeasured
  4. Functional flow at multiple fixtures
  5. Drain, waste and vent piping material
  6. Functional drainage at fixtures
  7. Visible leaks under sinks and at fixtures
  8. Toilets: secure, flush, leaks
  9. Tubs and showers: caulking, tile, surrounds
  10. Moisture readings around tubs and toiletsMeasured
  11. Water heater type, age and capacity
  12. Water heater venting and relief valve discharge
  13. Water heater seismic/strap and drain pan where required
  14. Gas piping visible portions
  15. Well equipment and pressure tank (rural homes)Manitoba
  16. Septic indicators and tank lid (rural homes)Manitoba
  17. Water softener or treatment equipment
  18. Cross-connection and backflow concerns
  19. Laundry hookups and drain
  20. Frozen-pipe risk areas in exterior wallsManitoba
  21. Hot water temperature at tapMeasured
  22. Lead or galvanized supply lines in older homesManitoba

Electrical22

  1. Service size and entrance type
  2. Main disconnect and panel location
  3. Panel cover removed and interior inspected
  4. Panel brand and known-issue models
  5. Breaker and wire size match
  6. Double-tapped breakers
  7. Grounding and bonding
  8. Aluminium branch wiringManitoba
  9. Knob-and-tube wiring signs in older homesManitoba
  10. Open junction boxes and splices
  11. Receptacles: polarity and grounding (sample)Measured
  12. GFCI protection at wet locationsMeasured
  13. AFCI protection where presentMeasured
  14. Two-prong receptacles
  15. Switches and light fixtures (sample)
  16. Extension cord or amateur wiring
  17. Smoke alarms: presence and test button
  18. Carbon monoxide alarms: presence
  19. Exterior and garage circuits
  20. Electric vehicle charger (if present)
  21. Solar panels and disconnect (if present)
  22. Hot spots at panel or breakers (thermal add-on)Measured

Fireplaces and wood stoves8

  1. Fireplace type and fuel
  2. Firebox, damper and hearth
  3. Hearth extension and clearances
  4. Gas fireplace operation and venting
  5. Wood stove clearance and floor protection
  6. Visible chimney flue and liner
  7. Creosote level where visible
  8. Recommendation for WETT inspection where requiredManitoba

Attic, insulation and air leakage12

  1. Attic access and safety
  2. Roof deck staining, rot and delamination
  3. Rafters, trusses and bracing
  4. Insulation type and approximate depthMeasured
  5. Vermiculite insulation (possible asbestos) flaggedManitoba
  6. Attic ventilation: intake and exhaust balance
  7. Frost and condensation evidenceManitoba
  8. Bathroom fans venting into attic
  9. Air sealing at top plates and penetrationsManitoba
  10. Pests and nesting evidence
  11. Knob-and-tube or splices in attic
  12. Thermal scan of ceilings for missing insulation (add-on)Measured

Interior20

  1. Walls and ceilings: cracks, stains, repairs
  2. Moisture readings at any stainMeasured
  3. Floors: slope, squeaks, soft spots
  4. Stairs: rise, run, headroom, handrails
  5. Guards at openings and landings
  6. Interior doors: operation and bindingManitoba
  7. Windows from inside (sample): operation, condensation
  8. Ceiling fans and lights (sample)
  9. Kitchen cabinets and counters
  10. Built-in appliances: basic operation
  11. Range anti-tip bracket
  12. Dishwasher drain loop and leaks
  13. Bathroom ventilation and mould signs
  14. Laundry area and dryer connection
  15. Closets and storage areas (accessible)
  16. Suspected asbestos materials flagged (not tested)
  17. Signs of pests
  18. Odours: sewer, gas, mould
  19. Indoor humidity readingMeasured
  20. Indoor CO2 / air quality screening (add-on)Measured

Life safety10

  1. Smoke alarms on every level
  2. Carbon monoxide alarms near bedrooms
  3. Bedroom egress windows
  4. Fire separation garage to house
  5. Trip hazards and missing guards
  6. Hot water scald riskMeasured
  7. Gas odour check
  8. Exposed wiring within reach
  9. Window fall protection on upper floors
  10. Pool or hot tub barriers (if present)

Report, data and insurance summary12

  1. Photo of every defect with location
  2. Severity: Safety, Repair, Monitor, Upgrade
  3. Plain-language implication for each finding
  4. Recommended trade for each repair
  5. Rough repair cost range where useful
  6. Ages of roof, furnace, water heater and AC
  7. Insurance-ready summary: wiring, plumbing, heating, roofManitoba
  8. Instrument readings recorded with time and locationMeasured
  9. Seasonal limitations noted (snow, frozen ground)Manitoba
  10. Maintenance priorities for the first year
  11. Report delivered as a searchable PDF with clickable contents
  12. Follow-up questions answered after delivery

Every check, every time.

Book an X-Point inspection or download the printable buyer's checklist.